Day Three – Thursday 25th May 2017

007:00 hours – Pre-start

07:10 hours – commencement of works (sieve using excavator).

08:00 hours – breakdown of excavator

Air Sampling:

Calibrator – Defender 510 s/n #9014

Cowl 004 pump #0518 at 1503 mL/minute
Cowl 005 pump #7149 at 1440 mL/minute
Cowl 006 pump #8214 at 1451 mL/minute

Weather:

Sunny, no breeze during the morning followed by light winds becoming south easterly 15 to 20 km/h in the afternoon then becoming light in the evening.

Fine, no breeze.

Real Time Dust Monitoring PM10s:

Upwind typically less than 0.055 mg/m3
Downwind typically less than 0.055 mg/m3

08:30 hours – removalist out of suits and working on erecting temp fence PCYC

09:00 hours to 13:00 hours recommence remediation of soil.

13:00 hours – removalist out of suits and installing sediment fence.

Daily Report: